Installation and Programming Manual
61
ZONES: MAINTENANCE (cont’d)
Quick Key Item Explanation
2 9 7 Zone Self Test
(cont’d)
i) and press [ENTER]
ii) at this display, press [8]
iii) and press [ENTER] again
iv) at this display, select the manner in which the UO will operate;
typically, by choosing PULSE N/O, the UO, acting like a
normally-open switch, will close for a predetermined period,
completing a circuit which can activate a noise source;
press [ENTER]
v) at this display, you may accept or rename the output if you
choose, and press [ENTER]
vi) finally, press [ENTER]; press the [TT] key, as required
UO=02 FOLLOWS:
1)SYSTEM ××
PATTERN UO=01:
2)PULSE N/O
SYS.EVENT: UO=02
1)BELL FOLLOW
SYS.EVENT: UO=02
8)SENSORS TEST
LABEL FOR UO=02
OUTPUT 02
INSTALLER PROG:
2)ZONES