UTILITY OUTPUT (cont’d)
Quick Key Pattern of Operation: Default Explanation
choose among the following patterns for the
selected utility output.
1 Pulse N/C 20
seconds
§ the Utility Output will always be activated (N/C)
before being triggered
§ when triggered it will de-activate for the
Pulse Duration specified below, then re-
activate automatically
§§ if selected, press [ENTER] and choose the
desired Pulse Duration, between 01-90
seconds; press [ENTER]
§ proceed to Choosing a Label for the UO, below
2 Latch N/C --- § the Utility Output will always be activated (N/C)
before being triggered
§ when triggered it will de-activate and remain so
(latch) until the operation restored.
§ press [ENTER]
§ proceed to Choosing a Label for the UO, below
3 Pulse N/O
20 seconds
§ the Utility Output will always be de-activated
(N/O) before being triggered
§ when triggered it will activate for the
Pulse Duration specified below, then de-
activate automatically
§ if selected, press [ENTER] and choose the
desired Pulse Duration, between 01-90
seconds; press [ENTER]
§ proceed to Choosing a Label for the UO, below
4 Latch N/O --- § the Utility Output will always be de-activated
(N/O) before being triggered
§ when triggered it will activate and remain so
(latch) until the operation restored.
§ press [ENTER]
§ proceed to Choosing a Label for the UO, below
LABEL FOR
UTILITY
OUTPUT
--- § for the user’s convenience (see page 30), you
may create and/or edit a ten character
description for the selected Utility Output
§ to do so, follow the instructions on keypad
labeling, found in the examples on pages 46
and 56
INSTALLER PROG:
3) UO
Vista de página 68
1 2 ... 64 65 66 67 68 69 70

Comentários a estes Manuais

Sem comentários